Created on 11/08/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
CABG
4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced
SERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The check
valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief
valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate
determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber
is atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATA
Cavity T-11A
Series 1
Capacity 30 L/min.
Pilot Ratio 4.5:1
Maximum Recommended Load Pressure at Maximum Setting 215 bar
Maximum Setting 280 bar
Factory Pressure Settings Established at 30 cc/min.
Maximum Valve Leakage at Reseat 0,3 cc/min.
Check Cracking Pressure 1,7 bar
Adjustment - Number of Counterclockwise Turns to Increase Setting 3
Reseat >85% of setting
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Model Weight 0.16 kg.
snhy.com/
CABG
Created on 11/08/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGE
H 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi
(210 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
TECHNICAL FEATURES
Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
Turn adjustment clockwise to decrease setting and release load.
Full clockwise setting is 200 psi (14 bar).
Free-flow check capacity (port 2 to port 1) is equivalent to the CAC* and CWC* models but the piloted-open flow capacity (port 1 to port 2) is reduced. See
performance curve.
All 3-port counterbalance and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size), however, the
model CABG has a reduced overall length, allowing for easier packaging.
Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
This valve has positive seals between all ports.
With vented valves, a lower pilot ratio may be required to achieve machine stability compared to non-vented valves.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: CABGLHNCONFIGURATION OPTIONS